CANUS/PortaDC™
Factory-built, liquid-cooled AI factories in two hulls. Owned by CANUS, leased to you by the IT-kW on sites that already have power and fibre. 120-day target from order.
01Why PortaDC
01 / 08
The concrete hall against the pod, on the four numbers that decide the build.

Lifted in.Not built on site.
Compute below, heat rejection above. One block in the 20 ft PortaDC20, two in the 40 ft PortaDC40.

20-ft · 450 kW IT
20-foot high-cube ISO two-module stack
Built for 3 to 5 high-density direct-to-chip racks (80 to 130+ kW/rack)
Compute below, heat rejection above, and three systems running through both.
Hull
System
Liquid to the chip in a closed loop. Heat goes to air on the roof. No evaporative water after fill.
415 V from a site that already has it, metered at the boundary and held there by FrontierGate™.
Power in and heat out, hardware-signed by LARUS AI™ into one record the tenant and the host both read.
Three leases on the same pod. Each is three numbers: a firm floor, a cushion and a flexible band.

01 · 24/7 firm production inference
The 24/7 live inference & decode pod. Firm floor plus cushion. Flexible band: zero. Never trimmed.
Target rent, power at cost
US$165–172 (A$235–245) per IT-kW-month

02 · Elastic batch, 25 to 40% contracted flex
The solar-sponge prefill, RAG & batch pod. Firm floor plus cushion plus a contracted 25 to 40% flexible band, tenant-run.
Target rent, power at cost
US$140–155 (A$200–220) per IT-kW-month

03 · Firm, dense training
The dense training & fine-tuning pod. Firm, dense liquid at 80 to 130 kW a rack.
Target rent, power at cost
US$180–187 (A$255–265) per IT-kW-month
Inside the pod
Every PortaDC is a complete 450 kW to 1.2 MW AI facility in one shell. Racks, liquid cooling, 415 V power and controls are designed, built and tested together before the pod leaves the factory.
450 kW ITLiquid-cooled to the chipClosed loopFactory-tested and recorded
You bring the GPUs. We bring the powered pod.
The engineering view01 / 06 · Two modules. One machine.
A rack-mounted unit in every pod. FrontierGate™ holds the boundary; LARUS AI™ signs what crossed it.

01The cushion, executed at the boundary
02The buffer carries the cushion
03Two channels, hardware-signed
Four layers, from the fence line to the certificate.
Sited inside fenced, 24/7 monitored solar-and-battery switchyards or secured industrial premises. No public foot traffic.
Solid corrugated weathering-steel walls with no air-intake louvres, internal deadbolts, vibration sensing and clean-agent fire detection and suppression to Australian standards.
LARUS AI™ hardware-signs boundary power and thermal delivery into one auditable ledger. Tamper-linked telemetry and independent hardware fault isolation sit alongside.
Every pod passes witnessed factory acceptance testing before it ships, then Australian integration and certification: AS/NZS 61439 switchboard, revenue-grade boundary metering, fire detection and suppression to Australian standards, statutory AS/NZS 3000 certification and site acceptance sign-off.
Target rent per IT-kW-month, power passed through at cost · US$ first, A$ beside
Elastic batch and prefill. 25 to 40% contracted flex, tenant-run.
24/7 firm production inference. Flexible band: zero.
Dense training. Firm liquid racks at 80 to 130 kW.
Six numbers that decide the build.
| Metro data centre | PortaDC | |
|---|---|---|
| Build cost per MW (excl. GPUs) | About 6× the pod | About 1/6th of a metro hallFactory-built pod on a ready pad |
| Time to powered racks | Years | 120 daysTarget deployment from order, on existing 415 V boards |
| Power | Metro tariff | Behind-the-meter renewable and hybrid tariffsPassed through at cost under transparent site schedules (shared under NDA) |
| Rack density supported | 10 – 25 kW / rack | 35 – 130+ kW / rackForge 80 – 130 kW, direct-to-chip liquid |
| Water consumption | Millions of litres / year | No evaporative water after fillClosed-loop liquid, rooftop dry cooler |
| All-in monthly cost | ~US$270 / IT-kW / month | ~US$213 / IT-kW / monthPulse target rent + power at cost · 12 to 21% under |
Indicative figures, confirmed in each lease. Power figures are planning blends, not a host tariff. Enquiries do not quote prices or reserve inventory.
Reserve capacity or host a pod
Three ways in. Pick your track; a named person replies within one business day. Enquiries do not quote prices or reserve inventory.

Up next
Inside the pod→